LR3000 Sürekli seviye sensörü (kılavuzlu dalga radarı) LR0000B-BR34AMPKG/US Tanklarda ve konteynerlerde güvenilir seviye kontrolü için Su, yağ ve soğutma için uygundur ants Açıkça görülebilen 4 haneli LED ekran Değerlendirme ünitesinden oluşan modüler sistem ve probe Product characteristics
LR3000
Sürekli seviye sensörü (kılavuzlu dalga radarı)
LR0000B-BR34AMPKG/US
Tanklarda ve konteynerlerde güvenilir seviye kontrolü için
Su, yağ ve soğutma için uygundur ants
Açıkça görülebilen 4 haneli LED ekran
Değerlendirme ünitesinden oluşan modüler sistem ve probe
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Probe length L[mm] | 100...1600 |
Process connection | threaded connection G 3/4 external thread |
Special feature | Gold-plated contacts |
Application | for industrial applications |
Media | Liquids |
Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation) |
Recommended media | water; hydrous media; oils; oil-based media |
Cannot be used for | See the operating instructions, chapter "Function and features". |
Process temperature[°C] | -25...80; (90 < 1 h ; see note under remarks) |
Pressure rating[bar] | 16 |
Vacuum resistance[mbar] | -1000 |
MAWP for applications according to CRN[bar] | 16 |
Operating voltage[V] | 18...30 DC |
Current consumption[mA] | < 30 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time[s] | < 3 |
Measuring principle | guided wave radar |
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Total number of outputs | 2 |
Output signal | switching signal; analogue signal; IO-Link |
Electrical design | PNP |
Number of digital outputs | 1 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC[V] | 2.5 |
Permanent current rating of switching output DC[mA] | 200 |
Number of analogue outputs | 1 |
Analogue current output[mA] | 4...20, invertible; (scalable) |
Max. load[Ω] | 500 |
Analogue voltage output[V] | 0...10, invertible; (scalable) |
Min. load resistance[Ω] | 2000 |
Short-circuit protection | yes |
Type of short-circuit protection | thermal, pulsed |
Overload protection | yes |
Probe length L[mm] | 100...1600 |
Active range A[mm] | L-40; (when set to oil and oil based media: L-60) |
Inactive range I1 / I2[mm] | 30 / 10; (when set to oil and oil based media: 30 / 30) |
Sampling rate[Hz] | 4 |
Setting range | ||
---|---|---|
Set point SP[mm] | 15...L-30 | |
Note on setpoint SP |
|
|
Reset point rP[mm] | 10... L-35 | |
Note on reset point rP |
|
|
In steps of[mm] | 5 | |
Hysteresis[mm] | > 5 |
Repeatability[mm] | ± 5 |
Measuring error[mm] | ± 7 |
Offset error[mm] | 5 |
Resolution[mm] | 1 |
Zero signal (voltage)[V] | 0 |
Zero signal (current)[mA] | 4.0 |
Full signal (voltage)[V] | 10 |
Full signal (current)[mA] | 20 |
Temperature drift per 10 K | ± 0.2 |
Communication interface | IO-Link | ||||
Transmission type | COM2 (38,4 kBaud) | ||||
IO-Link revision | 1.1 | ||||
SDCI standard | IEC 61131-9 CDV | ||||
SIO mode | yes | ||||
Required master port type | A | ||||
Process data analogue | 1 | ||||
Process data binary | 1 | ||||
Min. process cycle time[ms] | 2.3 | ||||
Supported DeviceIDs |
|
Ambient temperature[°C] | -25...60 |
Storage temperature[°C] | -40...80 |
Protection | IP 67 |
EMC |
|
||||||
Shock resistance |
|
||||||
Vibration resistance |
|
||||||
MTTF[years] | 196 | ||||||
UL approval |
|
Weight[g] | 378.4 |
Dimensions[mm] | Ø 50 / L = 99 |
Materials | stainless steel (304/1.4301); stainless steel (316L/1.4404); FKM; PBT; PC; PEI; TPE-V |
Materials (wetted parts) | stainless steel (303/1.4305); probe connection: stainless steel (316L/1.4435); PTFE; FKM; Sealing: NBR reinforced fibre |
Process connection | threaded connection G 3/4 external thread |