EUCHNER MGB2-L2HE-BR-U-S0-DY-R-164378 (Sip. No. 164378) Complete set MGB2-L2HE-BR (2 pushbuttons, emergency stop, with escape release, open-circuit current principle, door hinge on right) Guard locking with guard lock monitoring Emergency stop according to ISO 13850 2 illuminated pushbuttons 3 adhesive labels Cable entry M20 x 1.5 (order cable gland separa


| Installation orientation | any |
| Mechanical life | 1 x 10⁶ |
| Ambient temperature | -30 ... +55 °C |
| Material | |
| Housing | Die-cast zinc/stainless steel, powder-coated |
| Product version number | V2.0.0 |

| Installation orientation | Door hinge DIN right |
| Degree of protection | IP65 |
| Ambient temperature | -30 ... +55 °C |
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |

| Installation orientation | Door hinge DIN right |

| Item | Color | Extras | Switching element | Slide-in label | Version | Note slide-in label | Number | Designation1 | LED |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 PD + 1 NO | Emergency stop with monitoring contact | |||||||
| 2 | 1NO | Illuminated pushbutton | |||||||
| 3 | 1NO | Illuminated pushbutton |
| Current consumption | max. 24 mA |
| Controls and indicators | |
| Breaking capacity | max. 0.25 W |
| Switching voltage | 24 V |
| Switching current | 5 ... 10 mA |
| LED power supply | 24 V DC |
| Emergency stop | |
| Breaking capacity | max. 0.25 W |
| Switching voltage | 5 ... 24 V |
| Switching current | 1 ... 100 mA |
| Installation orientation | any |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65 (IP20) |
| Ambient temperature | |
| with UB = 24 V DC | -25 ... +55 °C |
| Material | Fiber glass reinforced plastic |
| B10D | Mission time | |
|---|---|---|
| Emergency stop | 0.13x106 | 20 y |
| Submodulbreite | 1 |
| Additional feature | incl. lens set, ID no. 120344 |

| Connection cross section | |
| (rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
| (rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
| (rigid/flexible) | 0.25 ... 1.5 mm² |
| Rated insulation voltage Ui | 75 V |
| Rated impulse voltage Uimp | 1.5 kV |
| Discrepancy time | |
| between FO1A and FO1B | max. 10 ms |
| Utilization category | |
| DC-13 | 24 V 150 mA |
| Risk time according to EN 60947-5-3 | max. 50 ms |
| Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
| Safety class | III |
| Transponder coding | Unicode |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring outputs OD, OT/C, OL, OI | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | UB-2 ... UB V DC |
| Output current | max. 50 mA |
| Safety outputs FO1A, FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| UFO1A /UFO1B LOW | 0 ... 1 V DC |
| UFO1A /UFO1B HIGH | UB-3,5 ... UB V DC |
| Output current | |
| per safety output FO1A / FO1B | 1 ... 150 mA |
| Turn-on time | max. 80 ms |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | min. 100 ms |
| Power supply UB | |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +20% |
| Current consumption | |
| IUB | max. 80 mA |
| Power supply IMP, IMM | |
| Solenoid operating voltage DC | |
| UIMP | 24 V DC -15% ... +20% |
| Current consumption | |
| IIMP | max. 375 mA |
| Test pulse duration | max. 5 ms |
| Test pulse interval | min. 100 ms |
| Ready delay | 5 s |
| Switching frequency | 0.25 Hz |
| Mechanical life | |
| in case of use as door stop, and 1 Joule impact energy | 0.2 x 10⁶ |
| when used as a door hinge and 2 joules of impact energy | 0.1 x 10⁶ |
| Total | 1 x 10⁶ |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65 |
| Ambient temperature | |
| with UB = 24 V DC | -30 ... +55 °C |
| Material | |
| Housing | Fiber glass reinforced plastic; die-cast zinc, nickel plated |
| Locking force FZh | 2000 N |
| Guard locking principle | Open-circuit current principle |
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Control of guard locking | PL e | 3 | 2.95x10-9 | 4 | 20 y |
| Monitoring of the guard position | PL e | 3 | 2.95x10-9 | 4 | 20 y |
| Monitoring of guard locking | PL e | 3 | 2.95x10-9 | 4 | 20 y |
| Slotkonfiguration | 1 |

| Connection type | Cable entries M20x1.5 |
| Installation orientation | any |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65 (IP20) |
| Ambient temperature | -25 ... +55 °C |
| Material | Fiber glass reinforced plastic |
| Slide-in label | |||||||
|
|||||||
| Additional feature | |||||||
| incl. socket connector set, ID no. 136572 | |||||||
| Incl. label holder, ID no. 156733 | |||||||

| Degree of contamination according to EN 60664-1 | 3 |
| Ambient temperature | -30 ... +55 °C |
| Material | Fiber glass reinforced plastic |
| Connection 1 | |
| Connection type | 2x M4 screws |
| Degree of protection | IP65 |
| Color | black |
| Additional feature | |
| incl. fixing screws | |
| incl. seal |