EUCHNER MGB2-L2HE-BR-U-S0-DY-R-164378 (Sip. No. 164378) Complete set MGB2-L2HE-BR (2 pushbuttons, emergency stop, with escape release, open-circuit current principle, door hinge on right) Guard locking with guard lock monitoring Emergency stop according to ISO 13850 2 illuminated pushbuttons 3 adhesive labels Cable entry M20 x 1.5 (order cable gland separa
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Ambient temperature | -30 ... +55 °C |
Material | |
Housing | Die-cast zinc/stainless steel, powder-coated |
Product version number | V2.0.0 |
Installation orientation | Door hinge DIN right |
Degree of protection | IP65 |
Ambient temperature | -30 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Installation orientation | Door hinge DIN right |
Item | Color | Extras | Switching element | Slide-in label | Version | Note slide-in label | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | 2 PD + 1 NO | Emergency stop with monitoring contact | |||||||
2 | 1NO | Illuminated pushbutton | |||||||
3 | 1NO | Illuminated pushbutton |
Current consumption | max. 24 mA |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | 24 V |
Switching current | 5 ... 10 mA |
LED power supply | 24 V DC |
Emergency stop | |
Breaking capacity | max. 0.25 W |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Installation orientation | any |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (IP20) |
Ambient temperature | |
with UB = 24 V DC | -25 ... +55 °C |
Material | Fiber glass reinforced plastic |
B10D | Mission time | |
---|---|---|
Emergency stop | 0.13x106 | 20 y |
Submodulbreite | 1 |
Additional feature | incl. lens set, ID no. 120344 |
Connection cross section | |
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
(rigid/flexible) | 0.25 ... 1.5 mm² |
Rated insulation voltage Ui | 75 V |
Rated impulse voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24 V 150 mA |
Risk time according to EN 60947-5-3 | max. 50 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs OD, OT/C, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UB-2 ... UB V DC |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-3,5 ... UB V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Turn-on time | max. 80 ms |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +20% |
Current consumption | |
IUB | max. 80 mA |
Power supply IMP, IMM | |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +20% |
Current consumption | |
IIMP | max. 375 mA |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Ready delay | 5 s |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.2 x 10⁶ |
when used as a door hinge and 2 joules of impact energy | 0.1 x 10⁶ |
Total | 1 x 10⁶ |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 |
Ambient temperature | |
with UB = 24 V DC | -30 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; die-cast zinc, nickel plated |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Control of guard locking | PL e | 3 | 2.95x10-9 | 4 | 20 y |
Monitoring of the guard position | PL e | 3 | 2.95x10-9 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 2.95x10-9 | 4 | 20 y |
Slotkonfiguration | 1 |
Connection type | Cable entries M20x1.5 |
Installation orientation | any |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (IP20) |
Ambient temperature | -25 ... +55 °C |
Material | Fiber glass reinforced plastic |
Slide-in label | |||||||
|
|||||||
Additional feature | |||||||
incl. socket connector set, ID no. 136572 | |||||||
Incl. label holder, ID no. 156733 |
Degree of contamination according to EN 60664-1 | 3 |
Ambient temperature | -30 ... +55 °C |
Material | Fiber glass reinforced plastic |
Connection 1 | |
Connection type | 2x M4 screws |
Degree of protection | IP65 |
Color | black |
Additional feature | |
incl. fixing screws | |
incl. seal |